  587b062lp thru 587b302lp 1 05057.r4 12/03 www .protekde vices.com low profile 240v ac power line surge suppressor only one name means protektion? 05057 applications ? hard wired equipment ac power protection ? load side distribution systems ? secondary protection for light industrial ac power iec compatibility (en61000-4) ? 61000-4-5 (surge): 1ka, 8/20s - level 4(line-line) & 333a level 4 (line-ground) features ? meets ansi/ieee c62.41 outdoor requirements ? listed to csa, file lr65240 (except 587b302lp) ? differential and common mode protection ? low clamping voltage ? nanosecond response time ? long life and maintenance free ? finger safe connectors mechanical characteristics ? plastic package ? weight: 360 grams (approximate) ? flammability rating ul 94v-0 ? device marking: part number, date code, logo, voltage and current rating description the 587b low profile (lp) series of 240 volt ac surge suppressors is designed for use by the oem, equipment installer and or maintenance contractor. these modules employ a three stage technology proven to be the most cost effective and reliable method in protecting sensitive electronic equipment from over voltage transients. this series is designed to protect ac powered equipment from the 6,000 volt peak open circuit voltage and 3,000 amp short circuit current as defined in ansi/ieee c62.41, category ci. the 587bxxxlp series offers a high degree of protection against 240 vac line emi noise. it is ideal for protecting 800 volt components because the solid state tvs technology assures that the line-to-neutral voltage will not exceed 800 volts. while the modules are designed for transient voltage protection, the advanced circuitry will also attenuate the amplitude and slow the rate of rise of high frequency noise acting as an emi filter. the 587bxxxlp series includes common mode and differential mode protection, which are effective in reducing interference from line to equipment and are effective in reducing equipment generated noise to meet fcc, vde and csa interfer- ence requirements u.s patent 4,563,720 0 10 20 30 40 50 60 figure 2 typical clamping action of a 15 amp module 0 10 20 30 40 50 60 kilovolts time - s 0 2 6 4 figure 1 transient voltage threat condition kilovolts time - s 0 2 4 8 6 figures 1 and 2 are photographs of digitized waveforms showing the typical clamping action of a 16 ampere module. a 12 ohm resistor is used to represent a 10 amp equipment load. the load is then subjected to the ansi/ieee c62.41 category ci test conditions (6,000v/3,000a). these photo- graphs contrast the effect on equipment with and without the protector.
2 www .protekde vices.com 05057.r4 12/03 587b062lp thru 587b302lp device characteristics arrester definitions clamping voltage: the clamping voltage of an arrester is the voltage that appears across its terminals during conduction of a transient current. standard wave form: the waveform of a surge current or voltage is designated by a combination of two numbers. the first number is for the time of the wave front expressed in microseconds from zero to the peak of the wave. the second number is for the time of the waveta il also expressed in microseconds from zero to the instant that the wavetail reaches one half of the crest or peak value, i.e., 8/20 s waveform. transient current: the transient current of an arrestor is the peak surge current which flows through the arrester when voltage clamping occurs. opera tion for maximum effectiveness, the protector should be installed directly after the ac line on/off switch and fuse. this will prot ect the electronics from the ac line switch arcing and the severe transients caused by a fuse clearing. some heat is produced when operating at full current load, and heat sinking may be required to maintain case temperature below 85c. the case temperature is measured at the center of the mounting surface. the unit should not be mounted to a low combusting temperature material such as wood. high energy transients will cause a large circulating current in the ac input line (2,500a is possible). to prevent electromag netic coupling, the ac line on the input side of the protector must be dressed away from other wiring, magnetic shielding may be required. in addition, th e electrical service must be connected to a low impedance earth ground. maximum ratings specifications @ 25c response to transient voltages clamping test condition differential (line-to-neutral) common (neutral-to-ground) (line-to-ground) operating line voltage: maximum line current: transient voltage: transient current: current leakage: line-to-neutral: neutral-to-ground: line-to-ground: storage & operating temperature: (measured at center of mounting surface) 240 vac + 10% 587b062lp: 6a 587B102LP: 10a 587b162lp: 16a 587b302lp: 30a 6000v peak 3000a peak @ 240 vac 1.0ma 1.0ma 1.0ma -40c to 85c protection mode maximum clamping voltage open circuit voltage @ 1.2/50 s short circuit current @ 8/20 s 800v 1000v 1000v 6000v 6000v 6000v 3000a 3000a 3000a
3 www .protekde vices.com 05057.r4 12/03 587b062lp thru 587b302lp copyright ? protek devices 2003 specifications: protek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except jedec). design changes: protek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer?s and that in furnishing engineering and technical assistance, protek assumes no responsibility with respect to the selection or specifications of such products. package outline & dimensions protek devices 2929 south fair lane, tempe, az 85282 tel: 602-431-8101 fax: 602-431-2288 e-mail: sales@protekdevices.com web site: www .protekde vices .com 1.63 ? (44.14 mm) 4.38 ? (111.3 mm) 3.81 ? (96.8 mm) 0.586 ? (14.43 mm) 3.50 ? (88.9 mm) 1.10 ? (27.9 mm) 2.30 ? (58.42 mm) line 1 out line 2 out neutral 1 out neutral 2 out ground out line in dia 0.181 ? neutral in ground in note: connector accepts 10-24 gauge wire. surgebuster ? ac line surge suppressor 587b162lp made in usa 240 vac 50/60 hz 16a ?


▲Up To Search▲   

 
Price & Availability of 587B102LP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X